PLC maintenance knowledge and inverter interference problem solution

Before diving into the PLC programming content, I’d like to share some essential maintenance tips that might be helpful for everyone. Let’s get started!

First, check for CPU issues. When the CPU is malfunctioning, ensure all internal bus connections are secure. To identify the faulty unit, try replacing each component one by one until the problem is resolved.

Next, if the memory is acting up, reprogramming might help determine if it's a software or hardware issue. If the error reappears, consider interference or a faulty memory chip. In such cases, replacing the memory could be necessary.

Then, look into input/output and expansion units. If an alarm occurs, first inspect the connectors and cable connections. Once the faulty unit is identified, replace it accordingly.

If the program isn’t executing, follow a systematic approach: check inputs, then the program execution, and finally the outputs.

For input checks, use the LED indicators or a programmer monitor. If the LED isn’t lit, there may be an issue with the external system. A multimeter can further confirm if the input unit is at fault.

During program execution, use the programmer’s monitor to verify the ladder logic. Mismatched results may point to a program error or a hardware issue.

For output checks, observe the LED status. If the output LED is on but no action occurs, the output unit or the connected load may be faulty.

Keep in mind that different PLC models may have varying LED configurations. Some LEDs are connected directly to the I/O unit, while others are linked through the CPU, so the diagnostic process may differ slightly.

If certain parts of the program aren’t running, check the input timing—especially for counters or step controllers. If the input time is too short, the system may not respond. Ensure the input time is longer than the maximum response time plus twice the scan time.

When power is briefly cut and the program is lost, check the battery and power supply circuit. Repeated power cycles can sometimes reset the system. If the issue persists after replacing the battery, it may indicate a memory or external circuit problem.

Also, check for noise interference from the machine system, as sudden power cuts often coincide with motor or winding operations.

If the PROM isn't working, first ensure it's properly inserted. If not, the chip may need replacement.

When the system stops after a power-on or reset, check for noise interference or poor internal contact. Gently tapping the PLC body can reveal loose connections. Also, verify that all cables and connectors are securely fastened.

Lastly, when dealing with inverter interference on analog signals, it's crucial to isolate the signal. For example, a Siemens PLC sending a 4-20mA signal to an inverter may fail due to interference. By using a signal isolation module, the issue can be resolved effectively.

In many industrial systems, PLCs and inverters work together, but they can interfere with each other. To prevent this, always use isolated power supplies, separate power and signal lines, shield cables, and apply signal isolation modules. Additionally, implement software filtering and keep signal and power grounds separate.

By following these best practices, you can significantly reduce the risk of interference and ensure smooth operation of your control system.